DB-5Q Ultra Low-Bleed GC/MS Columns
- Ultra Low-Bleed (Q) GC/MS Columns
Product Details
- Exceptionally low column bleed for improved sensitivity and mass spectral integrity
- Excellent peak symmetry for challenging, active analytes
- Outstanding column durability even at high operating temperatures
- Fast column conditioning
- Identical selectivity to DB-5ms and DB-5ms UI
- Available in 0.18 mm id column configuration for higher sample throughput and hydrogen carrier gas
- Individually tested with Uber One test probe mixture
- Performance Summary shipped with each column
- Compatible with any GC/MS system
- Key Literature
-
Get the Most from Your MS: Agilent J&W DB-5Q and HP-5Q GC Columns
Agilent J&W 5Q GC columns are designed for optimal analyte delivery, combining ultra inert performance with ultra low-bleed technology. The new gold standard for MS column reliability and productivity.
- Brochures
- English
- 16 Jun 2025
- 6.71 MB
Improved Thermal Stability of DB-5Q GC Column for Trace Level Controlled Substances
Increased thermal stability of the DB-5Q GC column with increased signal-to-noise for trace level concentrations of controlled substances results in improved quantitation of analytes.
- Application Notes
- English
- 21 Sep 2025
- 322.40 KB
Analysis of Volatile Compounds Identified in Rubber Gasket Extracts Using GC/MSD and High-Resolution GC/Q-TOF
This application note establishes a process for identifying GC-amenable extractables and leachable compounds using GC/MSD and GC/Q-TOF instruments.
- Application Notes
- English
- 16 Sep 2024
- 3.27 MB
- Application Notes
- Brochures
- Posters
- FAQs
-
Frequently Asked Questions about Gas Chromatography (GC)
Learn about GC techniques and approaches that can improve performance and productivity, and get information about some of the more common troubleshooting and maintenance procedures for your GC instruments.
Phillip Lynch
Lead Chemist, US Cannalytics
The new 5Q columns were essentially a plug and play update to our aging HP 5MS UI columns. We have noticed a decrease in the amount of noise/bleed from the columns themselves during the high ramp temperature regions of our analytical pesticide method. This has allowed us to add additional analytes to our method for orthogonal analysis between LC and GC techniques and therefore increasing our confidence during reporting. The attached chromatogram shows chlordanes at 0.5 ppb in-vial on a cannabis concentrate-type matrix. We are very satisfied with the column's performance in regard to retention time shifting, overall bleed reduction, and reproducibility.
View MoreLin Liu
Research Scientist, Chinese Research Academy of Environmental Sciences
The use of DB-5Q GC column provides faster conditioning, shorter analysis time, and greater convenience. It also results in lower column bleed, increased response, reduced baseline noise, improved sensitivity, ensuring smooth sample analysis.
View MoreDr. Frank David
Principal Scientist, RIC Group
The broad portfolio of Agilent columns that are available is really a key aspect in developing methods. What is also very important is that we have a broad range of lengths, internal diameters and film thicknesses.
View MoreVideos
Agilent Marks the 50th Anniversary of J&W GC Columns
2024 is the 50th anniversary of Agilent J&W GC columns. Throughout the last five decades, Agilent’s industry-first innovations have set the standard for the GC columns we know today. Agilent J&W also has the industry’s most extensive and innovative GC column portfolio, and every step of our manufacturing process is well established and controlled.