Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Chemical Group
- Compounds
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
This application note demonstrates the resolution and robustness made possible with an Agilent TED in combination with an Agilent 1290 Infinity II Bio LC at elevated temperatures.
- Publication Part Number: 5994-6105EN
- Created: 29 Oct 2025
- 828 KB
The development and manufacturing of biosimilars require comparability studies with innovator biotherapeutic products.
- Publication Part Number: 5994-1495EN
- Created: 15 Oct 2024
- 2 MB
A guide to find the right column for your characterization workflow. It includes advice and tips on method development, solvent choice, mobile phase modification, optimization, example separations, as well as ordering information.
- Publication Part Number: 5994-6123EN
- Created: 01 Oct 2023
- 36 MB
Application note for MS of AAV CQAs
- Publication Part Number: 5994-5110EN
- Created: 14 July 2022
- 698 KB
Critical Quality Attributes Peptide Mapping compendium
- Publication Part Number: 5994-0037EN
- Created: 23 Apr 2021
- 10 MB
Comparing maps of a mAb and its conjugates with the AdvanceBio Peptide Mapping column identifies peptides conjugated with a cytotoxic drug in an ADC digest.
- Publication Part Number: 5991-6191EN
- Created: 31 Mar 2021
- 221 KB
This app note presents a complete high-throughput workflow solution for sequence mapping analysis.
- Publication Part Number: 5991-7815EN
- Created: 23 Feb 2017
- 2 MB
This app note presents a high-throughput workflow that enables simultaneous, highly reproducible sample digestion and cleanup.
- Publication Part Number: 5991-7811EN
- Created: 15 Feb 2017
- 2 MB
Comparative analysis using LC-QTOF/MS between innovator and biosimilar of Rituximab
- Publication Part Number: 5991-6522EN
- Created: 01 Jan 2016
- 1 MB
This Application note demonstrates peptide mapping of a therapeutic mAb using Agilent 1260 Bio-inert Quaternary LC with fusion QbD method development software.
- Publication Part Number: 5991-6338EN
- Created: 01 Nov 2015
- 2 MB
Reversed-phase LC primary structure characterization workflow using Agilent AdvanceBio RP-mAb columns and Agilent 1260 Infinity Bio-Inert LC system
- Publication Part Number: 5991-6321EN
- Created: 10 June 2015
- 1 MB
An Agilent 2.7 μm HILIC column revealed a glycopeptide not seen by RP. HILIC can be orthogonal and complementary to RP for better retention of hydrophilic peptides.
- Publication Part Number: 5991-4903EN
- Created: 19 Aug 2014
- 2 MB
This Application Note shows the workflow solution for the physicochemical and biological characterization of a biosimilar and innovator rituximab.
- Publication Part Number: 5991-4920EN
- Created: 01 Aug 2014
- 2 MB
The Agilent AdvanceBio Peptide Mapping column separates mAb tryptic digests at low system pressures, providing UHPLC performance from HPLC operating conditions.
- Publication Part Number: 5991-3585EN
- Created: 06 Dec 2013
- 2 MB
| Publication Part Number | 5991-3585EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Peptide mapping is the common analytical technique for characterizing biologic therapeutic proteins.
- Publication Part Number: 5991-3600EN
- Created: 22 Nov 2013
- 1 MB
| Publication Part Number | 5991-3600EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
The AdvanceBio Peptide Mapping column gives 100% rhEPO sequence coverage with 45 glycopeptide matches.
- Publication Part Number: 5991-1813EN
- Created: 11 Feb 2013
- 576 KB
| Publication Part Number | 5991-1813EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This peptide mapping “how-to” helps you optimize your peptide mapping separations to achieve the best possible results.
- Publication Part Number: 5991-2348EN
- Created: 25 Apr 2014
- 5 MB