Refine Results
- Products
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
A powerful, non-destructive method is described for detecting food adulteration in spices using the Agilent 8700 LDIR chemical imaging system.
- Publication Part Number: 5994-8800EN
- Created: 10 Nov 2025
- 4 MB
Application of the Agilent Cary range of UV-Vis-NIR spectrophotometers for characterizing glazing materials in compliance with multiple internationally recognized standards.
- Publication Part Number: 5994-7537EN
- Created: 27 Aug 2024
- 983 KB
An end-to-end method with the Agilent Cary 5000 UV-Vis spectrometer and External DRA-2500 was used to measure the UV-Vis spectrum of four painted aluminum coupons.
- Publication Part Number: 5994-7538EN
- Created: 27 Aug 2024
- 692 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for Performance of compact visual displays — measuring angular reflectance of optically active materials using the Agilent Cary 7000 Universal Measurement Spe
- Publication Part Number: 5991-2508EN
- Created: 10 May 2021
- 370 KB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
How to do multi-angle UV-Vis-NIR measurements of multiple layer optical coatings
- Publication Part Number: 5991-4030EN
- Created: 14 Apr 2020
- 773 KB
| Korean (Korea) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
Efficient handling of large samples and multiple UV-Vis-NIR reflectance measurements using fully automated sample handling
- Publication Part Number: 5991-7530EN
- Created: 12 Mar 2020
- 1 MB
Agilent Cary 630 FTIR brochure
- Publication Part Number: 5990-8570EN
- Created: 08 July 2019
- 3 MB
| German (Germany) | Complete (PDF) |
|---|
Agilent spectroscopy solutions for the pharmaceutical laboratory
- Publication Part Number: 5991-4922EN
- Created: 16 June 2016
- 2 MB
| Korean (Korea) | Complete (PDF) |
|---|
Application note for identification and evaluation of coatings using hand-held FTIR
- Publication Part Number: 5990-8075EN
- Created: 23 Nov 2015
- 997 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for composite thermal damage – correlation of short beam shear data with FTIR spectroscopy
- Publication Part Number: 5990-7798EN
- Created: 23 Nov 2015
- 797 KB
Application note for epoxy primer thickness on aluminum measured with the handheld Agilent 4100 ExoScan FTIR
- Publication Part Number: 5990-7795EN
- Created: 23 Nov 2015
- 973 KB
10 and 45 Degree Specular Reflectance Accessories for the Agilent Cary 630 FTIR
- Publication Part Number: 5991-2101EN
- Created: 28 Mar 2022
- 521 KB
| Japanese (Japan) | Complete (PDF) |
|---|
Germanium ATR Accessory for the Agilent Cary 630 FTIR
- Publication Part Number: 5991-2099EN
- Created: 29 Apr 2016
- 1 MB
Diamond ATR, Attenuated Total Reflectance, ATR, Cary 630, FTIR, FT-IR, liquid analysis
- Publication Part Number: 5991-2197EN
- Created: 29 Apr 2016
- 2 MB
5 Bounce Zinc Selenide ATR Accessory for the Agilent Cary 630 FTIR
- Publication Part Number: 5991-2100EN
- Created: 29 Apr 2016
- 865 KB
The new 25x, 0.81 numerical aperture (NA) delivers spatialresolution to 1-2 microns
- Publication Part Number: 5991-6755EN
- Created: 04 Apr 2016
- 5 MB
使用 Agilent Cary 60 紫外-可見光分光光度計(jì)比較原研藥和生物仿制藥對(duì)
- Publication Part Number: 5991-7026CHCN
- Created: 01 July 2016
- 456 KB
Agilent Cary 630 ラボ用FTIR とAgilent 4500 可搬型FTIR による偽造醫(yī)薬品の検出
- Publication Part Number: 5991-6657JAJP
- Created: 11 Feb 2016
- 2 MB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
使用Agilent Cary Eclipse 熒光分光光度計(jì)和浸入式光纖探頭對(duì)飲料中的奎寧進(jìn)行定量分析
- Publication Part Number: 5991-6268CHCN
- Created: 07 Dec 2015
- 302 KB
使用安捷倫的 FTIR 光譜儀監(jiān)測(cè)電絕緣性油中的 DBPC 和 DBP 含量。
- Publication Part Number: 5991-6380CHCN
- Created: 12 Nov 2015
- 5 MB