Refine Results
- Products
-
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
- Compounds
-
Compounds
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
This application note describes a fully automated workflow for the quantification of volatile PFAS analytes in cosmetics.
- Publication Part Number: 5994-8752EN
- Created: 11 Nov 2025
- 1 MB
This application note describes the use and benefit of the Agilent Vaya Raman raw material identity verification system to measure through both transparent and opaque containers, specific to the formulation of cosmetic products.
- Publication Part Number: 5994-7595EN
- Created: 17 July 2024
- 584 KB
| Spanish (Spain) | Complete (PDF) |
|---|---|
| French (France) | Complete (PDF) |
| German (Germany) | Complete (PDF) |
| Italian (Italy) | Complete (PDF) |
This application note describes a rapid HPLC method using the Agilent 1260 Infinity II Prime LC system and the Agilent InfinityLab Poroshell 120 Aq-C18 (4.6 × 100 mm, 2.7 μm) column for 10 α-hydroxy acids.
- Publication Part Number: 5994-6084EN
- Created: 28 June 2023
- 413 KB
LC-ICP-MS method for the determination of trivalent and hexavalent chromium in toy materials to meet European regulation EN71-3:2012
- Publication Part Number: 5991-2878EN
- Created: 11 Aug 2021
- 698 KB
Application note for Performance of compact visual displays — measuring angular reflectance of optically active materials using the Agilent Cary 7000 Universal Measurement Spe
- Publication Part Number: 5991-2508EN
- Created: 10 May 2021
- 370 KB
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Korean (Korea) | Complete (PDF) |
This instruction sheet is designed to support the analyze of alcohol levels (ethanol and isopropanol) in hand sanitizers using the Cary 630 FTIR spectrometer with the MicroLab software.
- Publication Part Number: 5994-2827EN
- Created: 02 Dec 2020
- 2 MB
This routine method meets requirements of the world’s first quality and safety standards for e-cigarettes
- Publication Part Number: 5991-8676EN
- Created: 23 Sep 2018
- 782 KB
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Methods for the quantitative measurement of compounds in hair dyes include GC, GC/MS, LC, LC/MS, and so forth.
- Publication Part Number: 5991-7436EN
- Created: 19 Oct 2016
- 642 KB
Inertness performance of Agilent J&W DB-Wax Ultra inert GC column was evaluated by analyzing glycols in toothpaste samples using GC/MSD.
- Publication Part Number: 5991-6637EN
- Created: 02 Mar 2016
- 352 KB
Solutions for your analytical business
- Publication Part Number: 5991-5169EN
- Created: 21 Oct 2014
- 567 KB
Determination of Organotin Compounds in Toy Materials by Agilent 5977A GC/MSD to Meet European Regulation EN71-3: 2013, Migration of Certain Elements
- Publication Part Number: 5991-4658EN
- Created: 09 May 2014
- 1 MB
Application note for potential allergens in aromatherapy oils by GC/MS using an Agilent J&W DB-XLB capillary column
- Publication Part Number: 5990-5293EN
- Created: 18 Feb 2014
- 336 KB
Following the European Standard EN 71 part 11, an economical solution for the determination of VOCs was developed on a 7820A GC with a 5977E GC/MSD Sys configured to a 7667A
- Publication Part Number: 5991-3604EN
- Created: 15 Nov 2013
- 133 KB
| Publication Part Number | 5991-3604EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Agilent 5977EGCMS shows good performance on phthalates analysis
- Publication Part Number: 5991-3330EN
- Created: 18 Oct 2013
- 275 KB
| Publication Part Number | 5991-3330EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Development of analysis method for phthalates using the Agilent 1290 Infinity Method Development Solution with a phenyl-hexyl column.
- Publication Part Number: 5991-2784EN
- Created: 01 Sep 2013
- 2 MB
| Publication Part Number | 5991-2784EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This application note describes a fast and sensitive quantification for N-nitrosodiethanolamine (NDELA) in baby shampoo using LC/MS.
- Publication Part Number: 5991-1291EN
- Created: 17 Apr 2013
- 751 KB
Due to public health concerns, the Chinese government and the US Consumer Product Safety Commission (CPSC) both introduced test methods for the analysis of phthalate content
- Publication Part Number: 5990-4863EN
- Created: 03 Jan 2013
- 822 KB
UHPLC and LC/MS/MS methods were developed for separating components which are banned or restricted for use in hair dyes, on an Agilent Poroshell 120 Bonus-RP column.
- Publication Part Number: 5991-1289EN
- Created: 01 Oct 2012
- 619 KB
Application note for the analysis of bisphenol A leaching from baby feeding bottles
- Publication Part Number: 5990-9398EN
- Created: 01 Dec 2011
- 726 KB
| Korean (Korea) | Complete (PDF) |
|---|
SJ
- Publication Part Number: 5990-6861EN
- Created: 01 Dec 2010
- 2 MB
| Publication Part Number | 5990-6861EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|